APPLICATION
The continuous thermal conductivity analyzer has wide application in industry where it is desirable to analyze a two gas mixture. The thermal conductivity method is very stable in regards to span and zero drift. Applications include welding shield gas mixtures, food packaging mixtures, leak detection mixtures and heat treating atmospheres.
FEATURES
- rugged Thermco TC detector cell
- user programmable ranges with automatic linearization (digital models)
- built-in flow controls
- choice of panel or wall mount style
PRINCIPLES OF OPERATION
Each gas has the ability to conduct heat at a specific rate. This is known as the thermal conductivity of the gas. This property is utilized in the Thermco thermal conductivity detector. Heated metal filaments are exposed to the zero and sample gases. The amount of heat carried away by the gases changes the rate of cooling of the wire filament and, therefore its temperature. This temperature change causes a resistance change. Since the filaments are arranged in a Wheatstone bridge, the resistance change can be converted to an electrical current that is available as an output signal.
The digital versions of the analyzer contain a linearizer which allows for a digital readout and a 4-20 mA signal output.
SPECIFICATIONS
RANGE: Many ranges are available. Some common ranges are
shown on reverse side. Consult the Thermco sales engineer for details.
ACCURACY:
±0.3% of minor component over range of 0 - 10%, all ranges.
±0.5% of minor component over a range of 10.1% to 30.0% all ranges.
±1.0% of minor component over a range of 30.1% to 60.0% all ranges.
±2.0% of minor component over a range of 60.1% to 100.0% all ranges except CO2 in Ar, which has an accuracy of ±8%.
Example: For a 25% CO2 in Ar mixture, the analysis
will be between 24.5 and 25.5% CO2. This accuracy is
valid over a temperature range of 50° to 90°F (10° to 32°C).
RESOLUTION: 0.1% for digital meter.
RESPONSE TIME: 95% in 45 seconds for typical gas mixtures.
MAXIMUM DRIFT: Zero, ±2% of full range per week; span,
±1% of full range per month. This applies to typical ranges.
FREQUENCY OF CALIBRATION: Calibration is recommended once
per year when used under typical conditions.
AMBIENT TEMPERATURE LIMITS: -10°F to 110°F (-23°C
to 43°C).
UTILITIES REQUIRED:
Reference gas: The background gas in the mixture is required
to flow continuously at 0.5 SCFH. This should be a clean, dry, oil free gas. Gas pressure required is 1-150 PSIG.
Sample gas: The sample gas is required to flow continuously
at 1.0 SCFH. This should be a clean, dry, oil free gas. Gas pressure required is 1-150 PSIG, except gases containing H2 are 1-50 PSIG.
Power: 104-126 VAC, 50/60 Hz. 1 ampere standard; 204-240
VAC, 50/60 Hz. optional.
OUTPUT SIGNAL: 4-20 mA, proportional to gas analysis range
selected. This output is isolated and self-powered with a compliance
of 10 VDC. This output is not available on the analog meter versions.
ALARM RELAYS: 2 independent alarm relays, form C, with a
rating of 5 amperes@120/240 VAC or 28 VDC (resistive). Alarms are
not available on analog models. Note: When the
alarm package is specified these alarm relays are utilized in the
alarm package circuitry.
ENCLOSURE: Model 7000: General purpose indoor panel mount.
Model 7010: NEMA 4 wall mount.
DIMENSIONS/WEIGHT: Model 7000: 15.5" high, 13.6" wide, 10.3" deep (39.4, 34.5, 26.2cm). Model 7010: 15.5" high, 13"wide, 10.3" deep (39.4, 33, 26.2cm). Weight: 44 lb. (20 kg.)
CELL/FILAMENT MATERIAL: Tungsten filaments with brass block
and gold plated filament holder.
|
TC GAS ANALYSIS AND THERMCO
Thermco has been manufacturing thermal conductivity gas analyzers
since the establishment of Thermco in 1951. The complete process
of manufacturing, starting with the production of the cell filaments,
is performed at our factory in LaPorte, Indiana, U.S.A. Each step
of the manufacturing process is planned to produce an analyzer that
is rugged and highly accurate. Thermco detector cells are designed
not to "burnout" under conditions where there is no gas
flow through the cell. Analyzers which have been functioning for
over 20 years without replacement of any major parts is common.
COMMON MIXTURES MEASURED

USER PROGRAMMABLE RANGES:
Linearization data for 6 standard ranges are built into the digital
analyzers. These are 0-100% CO2 in Ar, 0-100% O2 in Ar, 0-100% He in Ar, 0-100% H2 in Ar, 0-100% CO2 in N2, 0-100% H2 in N2. The user may reprogram the analyzer to any of these ranges, except non-H2 ranges can not be converted to H2 ranges. Single point recalibration will be required after a range change. The analyzer will be factory calibrated for the range selected. A custom range is available for two gas mixtures not listed above. Data for the custom range may be programmed into the analyzer by the factory or the user.
MODEL NUMBER SYSTEM

E-explosion hazard reduction. This is a 5 SCFH purge of N2
or Ar which is required to purge into the enclosure for analyzers
with H2 in the sample gas.
F-filter (maximum sample pressure is 125 PSIG)
H-horn. The horn is shipped loose to be wired by user to alarm package.
P-pump (required for sample pressures less than 1 PSIG)
Note: All digital models include alarm relays and linearizer.
Analog versions are only available for ranges 0-50% CO2 in Ar and
0-10% O2 in Ar. Analyzers with H2 or exothermic gas must be ordered
with the "E" option.
Gas Index
A=argon, Ai=air, C=carbon dioxide, E=exothermic gas, H=hydrogen,
He=helium, N=nitrogen, O=oxygen, S=sulfur hexafluoride
WARNING
Improper use of this product can cause serious injury or property
damage. Personnel dealing with this equipment should read and understand
warning labels and instruction manuals provided by
Thermco.
NOTICE
In the interest of continued product development, Thermco reserves
the right to change design features without prior notice. Sale of
this equipment is under the terms of the Thermco warranty available
upon request.
ORDERING INFORMATION
Orders may be placed directly with Thermco or through many local
gas suppliers. When ordering, please generate the proper model number.
|