2 GAS MIXERS NONFLAMMABLE GAS UP TO 750 SCFH FLOW RATE

Model Flow Rate SCHF Gas Mixture Typical Application Installation Drawings Outline Drawings
9775 0-350 0-50% He in Ar Welding Shield Gas pdf pdf
8500 0-750 0-50% CO2 in Ar Welding Shield Gas pdf pdf
8505 0-750 0-10% O2 in Ar Welding Shield Gas pdf pdf
8510 0-750 Fixed Ratio, Non O2, Non H2 Welding Shield Gas, Leak Detection pdf pdf
8515 0-750 Welding Shield Gas Fixed Ratio with O2, Non H2 pdf pdf
8525 0-750 0-100% CO2 in N2 Food Packaging pdf pdf
9520 0-750 0-100% O2 in CO2 Food Packaging pdf pdf

2 GAS MIXERS NONFLAMMABLE GAS 2000 SCFH AND GREATER

Model Flow Rate SCFH Gas Mixture Typical Application Installation Drawings Outline Drawings
6105 0-2,000 0-30% CO2 in Ar
0-10% O2 in Ar
0-50% He in Ar
0-50% CO2 in N2
(Others Available)
Welding, Food Packaging, Indoor pdf pdf
8105 0-2,000 Same as Model 6105 Welding, Food Packaging, Outdoor pdf pdf
8106 0-2,000 0-30% CO2 in Ar
0-10% O2 in Ar
0-50% He in Ar
Welding Shield Gas, Outdoor, No Analyzer pdf pdf
6205 0-5,000 Same as Model 6105 Welding, Food Packaging, Indoor pdf pdf
8205 0-5,000 Same as Model 6105 Welding, Food Packaging, Outdoor pdf pdf
6305 0-10,000 Same as Model 6105 Welding Shield Gas, Indoor pdf pdf
8305 0-10,000 Same as Model 6105 Welding Shield Gas, Outdoor pdf pdf
6405 0-20,000 Same as Model 6105 Welding Shield Gas, Indoor pdf unavailable
8405 0-20,000 Same as Model 6105 Welding Shield Gas, Outdoor pdf unavailable

2 GAS MIXERS, FLAMMABLE GAS

Model Flow Rate SCFH Gas Mixture Typical Application Installation Drawings Outline Drawings
8520 0-500 Fixed Ratio, H2/Ar Plasma Welding pdf pdf
8300 0-2,000 0-10% H2 in N2
0-20% H2 in N2
0-50% H2 in N2
50-80% H2 in N2
Furnace Atmosphere pdf pdf
8350 0-2,000 0-10% H2 in Ar Plasma Welding pdf pdf
8400 0-5,000 Same as Model 8300 Furnace Atmosphere pdf pdf
8450 0-5,000 0-10% H2 in Ar Plasma Welding pdf pdf
8600 0-10,000 Same as Model 8300 Furnace Atmosphere pdf pdf

3 GAS MIXERS

Model Flow Rate SCFH Gas Mixture Typical Application Installation Drawings Outline Drawings
8610 0-750 Fixed Ratio, Non O2 Welding Shield Gas, Laser Gas pdf pdf
8615 0-750 Fixed Ratio, with O2 Welding Shield Gas pdf pdf
8110 0-2,000 Fixed Ratio, Non O2 Welding Shield Gas, Laser Gas pdf pdf
8115 0-2,000 Fixed Ratio, with O2 Welding Shield Gas pdf pdf
8210 0-5,000 Fixed Ratio, Non O2 Welding Shield Gas pdf pdf
8215 0-5,000 Fixed Ratio, with O2 Welding Shield Gas pdf pdf